Nieinwazyjne metody pomiaru ciśnienia wewnątrzczaszkowego (Polish Wikipedia)

Analysis of information sources in references of the Wikipedia article "Nieinwazyjne metody pomiaru ciśnienia wewnątrzczaszkowego" in Polish language version.

refsWebsite
Global rank Polish rank
4th place
7th place
2nd place
6th place
low place
low place

doi.org

doi.org

  • Petkus V, Ragauskas A, Jurkonis R. Investigation of intracranial media ultrasonic monitoring model. „Ultrasonics”. 40 (1–8), s. 829–33, 2002. DOI: 10.1016/S0041-624X(02)00216-0. PMID: 12160053. 
  • Michaeli D, Rappaport ZH. Tissue resonance analysis; a novel method for noninvasive monitoring of intracranial pressure. Technical note. „J. Neurosurg.”. 96 (6), s. 1132–7, 2002. DOI: 10.3171/jns.2002.96.6.1132. PMID: 12066918. 
  • Ragauskas A, Daubaris G, Ragaisis V, Petkus V. Implementation of non-invasive brain physiological monitoring concepts. „Med Eng Phys”. 25 (8), s. 667–78, 2003. DOI: 10.1016/S1350-4533(03)00082-1. PMID: 12900182. 
  • Schmidt B, Czosnyka M, Raabe A, etal. Adaptive noninvasive assessment of intracranial pressure and cerebral autoregulation. „Stroke”. 34 (1), s. 84–9, 2003. DOI: 10.1161/01.STR.0000047849.01376.AE. PMID: 12511755. 
  • Shimbles S, Dodd C, Banister K, Mendelow AD, Chambers IR. Clinical comparison of tympanic membrane displacement with invasive intracranial pressure measurements. „Physiol Meas”. 26 (6), s. 1085–92, 2005. DOI: 10.1088/0967-3334/26/6/017. PMID: 16311455. 

dx.doi.org

  • G. Cennamo, M. Gangemi, L. Stella, The correlation between endocranial pressure and optic nerve diameter: an ultrasonographic study, [w:] K.C. Ossoinig (red.), Ophthalmic Echography, t. 48, 1987 (Documenta Ophthalmologica Proceedings), s. 603–6, DOI10.1007/978-94-009-3315-6_99, ISBN 978-94-010-7988-4.

nih.gov

ncbi.nlm.nih.gov

  • Allocca JA. Noninvasive monitoring of intracranial pressure. „Med Electron”. 13 (1), s. 81–5, 1982. PMID: 10254587. 
  • Petkus V, Ragauskas A, Jurkonis R. Investigation of intracranial media ultrasonic monitoring model. „Ultrasonics”. 40 (1–8), s. 829–33, 2002. DOI: 10.1016/S0041-624X(02)00216-0. PMID: 12160053. 
  • Michaeli D, Rappaport ZH. Tissue resonance analysis; a novel method for noninvasive monitoring of intracranial pressure. Technical note. „J. Neurosurg.”. 96 (6), s. 1132–7, 2002. DOI: 10.3171/jns.2002.96.6.1132. PMID: 12066918. 
  • Ragauskas A, Daubaris G, Ragaisis V, Petkus V. Implementation of non-invasive brain physiological monitoring concepts. „Med Eng Phys”. 25 (8), s. 667–78, 2003. DOI: 10.1016/S1350-4533(03)00082-1. PMID: 12900182. 
  • Schmidt B, Czosnyka M, Raabe A, etal. Adaptive noninvasive assessment of intracranial pressure and cerebral autoregulation. „Stroke”. 34 (1), s. 84–9, 2003. DOI: 10.1161/01.STR.0000047849.01376.AE. PMID: 12511755. 
  • Shimbles S, Dodd C, Banister K, Mendelow AD, Chambers IR. Clinical comparison of tympanic membrane displacement with invasive intracranial pressure measurements. „Physiol Meas”. 26 (6), s. 1085–92, 2005. DOI: 10.1088/0967-3334/26/6/017. PMID: 16311455. 

nlm.nih.gov

noninvasiveicp.com